Role & Building Type
Location
Compliance Path
Base Requirements
Earn Points
Results
Wireframe note: This is the entry point. User picks role first โ€” language adapts throughout. Then picks residential vs commercial.
Step 1 of 6

Let's get started

Tell us a bit about who you are and what you're building. We'll tailor the tool to your situation.

๐Ÿ‘ค What best describes your role?
๐Ÿ—๏ธ
Builder / Developer
๐Ÿ“
Designer / Architect
โš™๏ธ
Engineer
๐Ÿ›๏ธ
Building Official
๐Ÿ  What type of building are you working on?
Residential
Houses, semi-detached, row houses, small multi-unit residential. NBC 2025 Part 9.
Commercial
Office, retail, institutional, industrial. National Energy Code 2025 (NECB).
Interior volume of heated/cooled space. How to calculate โ†—
Building includes an HRV or ERV (heat recovery ventilator)
โ„น๏ธ
An HRV or ERV is required to achieve any tier under the tiered prescriptive path. If your building doesn't include one, you won't be able to earn conservation points.
Wireframe note: City dropdown auto-fills HDD and zone. Map highlights the zone in colour. Manual HDD entry for unlisted locations.
Step 2 of 6

Where is the building located?

Your climate zone determines which code values apply. Manitoba has three zones based on heating degree-days.

Don't see your location? Enter HDD manually
[ Manitoba climate zone map โ€” Zone 7A highlighted in blue ]
Heating Degree Days
โ€”
HDD at 18ยฐC
Climate Zone
Zone โ€”
5,000โ€“5,999 HDD
This means
Code tables for your zone apply to your building. These are the values we'll check against throughout the tool.
๐Ÿ“„ NBC 2025 Appendix C โ€” Climate Data โ†—
Wireframe note: Three path cards. Tiered Prescriptive is recommended and pre-selected. Performance card is shown but labelled "screening only."
Step 3 of 6

Choose your compliance path

Manitoba requires Tier 3 for residential buildings. There are three ways to demonstrate your building meets this requirement.

Prescriptive (Base)
Meet the minimum insulation and window values in the code. Achieves Tier 1 only โ€” not sufficient for Manitoba.
NBC 2025 Sections 9.36.2โ€“9.36.4
Performance
Energy modelling to demonstrate overall performance. Screening estimate only โ€” certified HOT2000 model required for permits.
NBC 2025 Section 9.36.7
โ„น๏ธ
Why Tiered Prescriptive? It's the most flexible path โ€” no energy modelling required, and you can earn points from a wide range of upgrades. A cold-climate heat pump alone can get you to Tier 3 in one measure.
๐Ÿ“„ Understanding the Tiers โ€” KnowYourCodesMB.ca โ†—
Wireframe note: All base minimums must pass before earning points. Pass/fail is live as values are entered. Code ref link on every row.
Step 4 of 6

Base requirements Zone โ€”

These minimum values must be met before you can earn any conservation points. All components must pass.

โ„น๏ธ
If your building includes an HRV, Table 9.36.2.6.-B values apply (slightly lower minimums). Set the HRV toggle on Step 1 to confirm. ๐Ÿ“„ NBC 2025 Table 9.36.2.6.-B โ†—
๐Ÿงฑ Above-Ground Opaque Assemblies
Component
Your value
Minimum (Zone 7A)
Status
Above-grade walls
Effective RSI, (mยฒยทK)/W
๐Ÿ“„ Table 9.36.2.6.-B โ†—
โ‰ฅ 2.97 RSIR16.9 imperial
โ€”
Ceilings below attics
Effective RSI, (mยฒยทK)/W
๐Ÿ“„ Table 9.36.2.6.-B โ†—
โ‰ฅ 8.67 RSIR49.2 imperial
โ€”
Cathedral ceilings / flat roofs
Effective RSI, (mยฒยทK)/W
๐Ÿ“„ Table 9.36.2.6.-B โ†—
โ‰ฅ 5.02 RSIR28.5 imperial
โ€”
Floors over unheated spaces
Effective RSI, (mยฒยทK)/W
๐Ÿ“„ Table 9.36.2.6.-B โ†—
โ‰ฅ 5.02 RSIIf applicable
N/A
๐ŸชŸ Fenestration & Doors
Wireframe note: User can enter either U-value OR Energy Rating โ€” whichever is on their product spec sheet.
Component
Your value
Maximum (Zone 7A)
Status
Windows & doors
U-value W/(mยฒยทK) or Energy Rating
๐Ÿ“„ Table 9.36.2.7.-A โ†—
U โ‰ค 1.61or ER โ‰ฅ 25
โ€”
๐Ÿ—๏ธ Below-Grade Assemblies
Component
Your value
Minimum (Zone 7A)
Status
Foundation walls
Effective RSI, (mยฒยทK)/W
๐Ÿ“„ Table 9.36.2.8.-B โ†—
โ‰ฅ 2.98 RSIR16.9 imperial
โ€”
Slab-on-grade
Effective RSI, (mยฒยทK)/W
๐Ÿ“„ Table 9.36.2.8.-B โ†—
โ‰ฅ 2.84 RSIR16.1 imperial
โ€”
โฌœ
Enter your values above to check base requirements. All components must pass before proceeding.
Wireframe note: Accordion per category. Each shows points earned. Running total in sidebar. Categories sorted by highest-impact first for Zone 7A.
Step 5 of 6 โ€” Tiered Prescriptive Path โ€” Zone 7A

Earn conservation points

You need 20 points total, with at least 5 from envelope measures. Enter your specs โ€” points calculate automatically. You don't need to fill every category.

โ„น๏ธ
Select your specs below โ€” points calculate as you go. You need 20 points total, with at least 5 from envelope measures.
Space Heating โ€” Cold-Climate Heat Pump
Points available: up to ~35 pts
Highest impact โšก โ–ผ
๐Ÿ’ก
A cold-climate air-source heat pump (COP โ‰ฅ 1.8 at -15ยฐC, capacity โ‰ฅ 70% at -15ยฐC vs 8.3ยฐC) earns significantly more points than a standard heat pump. This is the fastest single path to Tier 3.
๐Ÿ“„ NBC 2025 Table 9.36.9.9.-F โ†—
Found on the product spec sheet or AHRI certificate.
HSPF2 VPoints (Zone 7A)
โ‰ฅ 6.729.5
โ‰ฅ 7.631.4
โ‰ฅ 8.332.9 โ† if selected
โ‰ฅ 9.635.5
Airtightness Envelope
Points available: up to ~15 pts
Optional โ€” requires blower door test โ–ผ
โ„น๏ธ
Points are awarded for tested airtightness better than the code default. A blower door test is required โ€” the default assumed airtightness is 3.2 ACH@50Pa if untested.
๐Ÿ“„ NBC 2025 Table 9.36.9.8. โ†—
LevelPoints (Zone 7A)
AL-2A3.8
AL-3A7.6
AL-4A11.4
AL-5A14.7
Above-Grade Walls Envelope
Points available: up to ~10 pts
not entered โ–ผ
Effective RSI accounts for thermal bridging through studs. CWC Effective R Calculator โ†—
Minimum Effective RSIImperialPoints (Zone 7A)
3.08 (base minimum)R17.50
3.69R21.04.4
3.85R21.95.2
3.96R22.55.8
4.29R24.47.4
4.57R25.98.4
5.01R28.410.0
๐Ÿ“„ NBC 2025 Table 9.36.9.5.-A โ†—
Windows & Doors Envelope
Points available: up to ~12.6 pts
not entered โ–ผ
From ENERGY STAR or NFRC label
Max U-valueMin ERPoints (Zone 7A)
1.61 (base min)250
1.44291.8
1.22345.5
1.05408.9
0.944210.7
0.824412.6
๐Ÿ“„ NBC 2025 Table 9.36.9.6. โ†—
HRV / ERV Efficiency
Points available: up to 5.3 pts
not entered โ–ผ
Found on the HVI Certified Products Directory or product spec sheet.
SREPoints (Zone 7A)
60%3.7
70%4.2
80%4.8
85%5.0
โ‰ฅ 90%5.3
๐Ÿ“„ NBC 2025 Table 9.36.9.9.-A โ†—
Service Water Heating Mechanical
Points available: up to 3.1 pts
โ–ผ
๐Ÿ“„ NBC 2025 Table 9.36.9.10.-A โ†—
Foundation Walls Envelope
Points available: up to ~8 pts
โ–ผ
๐Ÿ“„ NBC 2025 Table 9.36.9.7.-A โ†—
Building Volume Envelope
Points available: up to 10 pts (if volume โ‰ค 390 mยณ)
โ–ผ
โ„น๏ธ
Points available if total conditioned volume โ‰ค 390 mยณ (single building), or if each dwelling unit โ‰ค 230 mยณ. Enter your volume on Step 1 โ€” check if each unit qualifies for the 10-point option.
๐Ÿ“„ NBC 2025 Table 9.36.9.11. โ†—
Additional categories: Ceilings / Attics ยท Cathedral Ceilings ยท Exposed Floors ยท Slabs ยท Drain Water Heat Recovery ยท Gas Furnace
Step 6 of 6 โ€” Results

Compliance Summary

Complete earlier steps to populate your project summary.

Wireframe note: Two states shown โ€” "not yet compliant" (current) and "compliant" (toggle below to preview). Gap analysis shows specific upgrade suggestions.
Manitoba Requirement
Tier โ€”
Enter your specs on Step 5 to calculate your tier and point total.
โšก How to reach Tier 3 (need 5.3 more points)
๐Ÿ’จ
Upgrade to a cold-climate heat pump (HSPF2 โ‰ฅ 6.7) โ†’ earns 29.5 points. Replaces gas furnace entirely. +29.5 pts โ€” gets you to Tier 3 in one step.
๐Ÿ”’
Airtightness testing (AL-2A blower door) โ†’ earns 3.8 points. Combined with a small wall upgrade โ†’ covers the 5.3 gap. +3.8 pts
๐ŸชŸ
Upgrade windows to U โ‰ค 1.22 (ER โ‰ฅ 34) โ†’ earns 5.5 pts (up from current 1.8 pts). +3.7 pts โ€” nearly closes the gap alone.
๐Ÿ“‹ Component Summary
ComponentValueCode ReferencePoints
Above-grade wallsโ€”Table 9.36.9.5.-Aโ€”
Windows & doorsโ€”Table 9.36.9.6.โ€”
Foundation wallsโ€”Table 9.36.9.7.-Aโ€”
HRV efficiencyโ€”Table 9.36.9.9.-Aโ€”
Water heatingโ€”Table 9.36.9.10.-Aโ€”
Space heatingโ€”โ€”โ€”
Airtightnessโ€”โ€”โ€”
Building volumeโ€”Table 9.36.9.11.โ€”
Totalโ€” / 20